Nullam dignissim, ante scelerisque the is euismod fermentum odio sem semper the is erat, a feugiat leo urna eget eros. Duis Aenean a imperdiet risus.

X201U
X201U

X201U

Modular design, simple structure, non-directional transmission, suitable for all kinds of steel fermentation tanks.

Product features and advantages

National Invention Patent No.: ZL202022562733.8 Patent No.: ZL 2 0 2 0 2 2 5 6 2 7 3 3 . 8

Parameter

Design Pressure (MPa) -0.1〜0.35MPa
Design Temperature (°C) -40~120° C

When the temperature exceeds the limit, a cooling tank must be added, and the installation height should be increased by 80mm.

Speed (m/s) ≤2M/S
Medium Suitable for general working conditions; select the appropriate medium based on the type of rubber.

 

Application areas/scenarios

As a professional manufacturer of mechanical seals, we focus on providing products and services to industries such as oil and gas, chemicals, pharmaceuticals, food, new energy, water treatment, and new materials.

FAQ

1. Leakage Issues (Most Common)

– Static sealing surface leakage: Check if the stationary ring seals (O-rings, V-rings) are aged, deformed, or missized. Replace with seals of the same specifications that are resistant to the medium and temperature. If the clearance between the stationary ring and the gland is too large, the stationary ring needs to be re-machined or replaced.

– Dynamic sealing surface leakage: Check the sealing end faces of the dynamic and stationary rings for scratches, wear, or chipping. Minor scratches can be repaired by grinding; for severe scratches, replace the sealing ring directly. Also, confirm if the spring compression is appropriate. If insufficient compression, add gaskets; if excessive compression, reduce the number of gaskets.

– Leakage at the bushing-shaft mating point: Check if the bushing seal is damaged or if the clearance between the bushing and the shaft is too large. Replace the seal or re-grind the bushing.

2. Abnormal Wear

– Excessive end face wear: If due to particulate impurities in the medium, a filter needs to be installed; if due to insufficient lubrication, a self-lubricating seal such as an impregnated graphite ring can be used, or an external flushing fluid (such as a clean liquid of the same medium) can be introduced.

– Shaft sleeve wear: Replace the shaft sleeve with one made of wear-resistant material, and adjust the coaxiality of the sealing cavity and the shaft to avoid uneven wear.

3. Overheating and Burnout

– Excessive sealing cavity temperature: Check for blockages in the cooling system and clean the cooling pipes; if the medium temperature itself is too high, use high-temperature resistant sealing materials (such as silicon nitride ceramic rings or fluororubber sealing rings).

– Spring failure leading to poor end-face contact: Replace fatigued or corroded springs with corrosion-resistant spring materials such as stainless steel, and ensure uniform spring compression.

4. Vibration and Abnormal Noise

– Coaxiality Deviation: Recalibrate the coaxiality of the pump shaft and motor shaft, adjust the radial runout of the sealing cavity and shaft, and control it within the allowable range.

– Loose Parts: Check whether the gland bolts and drive pins are loose, tighten the bolts evenly according to the specified torque, and replace worn drive pins.

5. Short lifespan of the seal

– Material mismatch with the medium: Replace the sealing material according to the characteristics of the medium (e.g., use Hastelloy or PTFE for corrosive media; use silicon carbide for high-temperature media).

– Improper installation: Strictly follow the installation specifications to avoid impact or scratches on the sealing surface, and ensure that no impurities enter the sealing cavity during installation.

PRODUCTS

PRODUCTS

View More
News

News

View More

17/ July

Single vs Double Mechanical Seal: Differences, Applications and Selection Guide

Compare single vs double mechanical seals by application, leakage risk, barrier fluid needs, and buying tips for pumps and reactors.
Learn More
Single vs Double Mechanical Seal Differences, Applications and Selection Guide

16/ July

Mechanical Seal vs Packing: Which Is Better for Industrial Pumps?

Compare mechanical seal vs packing for pumps by leakage, cost, maintenance, retrofit needs, and supplier selection for industrial applications.
Learn More
Mechanical Seal vs Packing Which Is Better for Industrial Pumps

10/ July

Mechanical Seal Material Selection Guide: Faces, Elastomers and Metals

Mechanical seal material selection guide covering face materials, elastomers and metals for chemical compatibility, temperature, pressure and abrasion.
Learn More
Mechanical Seal Material Selection Guide Faces, Elastomers and Metals

9/ July

How to Select a Glass-Lined Reactor Mechanical Seal: Single vs Double, Dry vs Wet

Learn how to choose a glass-lined reactor mechanical seal by comparing single vs double and dry vs wet designs, failure risks, and supplier criteria.
Learn More
How to Select a Glass-Lined Reactor Mechanical Seal Single vs Double, Dry vs Wet
What We Do

Services we Offer

No matter what your mechanical seal needs may be, we’re here to help. Contact us today to learn more about our
services and how we can assist you with all of your needs.
service4

One-Stop Service System

We are committed to providing clients with one-stop service throughout the entire project lifecycle, ensuring efficiency, reliability, and worry-free operation from selection to operation.
decorate
Looking for a trusted mechanical seal supplier for your global projects?

Contact Us

Our factory has extensive export experience, and our products meet ISO standards. We offer a one-stop service from product selection to after-sales support, including on-site installation guidance. Whether you need small samples or large orders, we can meet your needs. Send us an inquiry today to discuss your project details and get a sample quote.

    Your Name*

    Email*

    Tel*

    WhatsApp*

    Message*

    Products
    Contacts
    WhatsApp
    Email